With Bridgeport bushings, you can do more than just protect conductors. Mighty-Rite® Split Bushings allow for installation before or after a wire pull. Bridgeport also has your standard conduit, grounding and insulating bushing solutions.
-
Bushing, Reducing, SteelUsed to reduce the size of internal female threads. 1/2" thru 2" steel, 2 1/2" thru 4" malleable iron.
-
-
-
-
Bushing, Insulated, Grounding, Malleable IronUsed with locknut to terminate service conduit to cabinet. Lug provided for bonding jumper to neutral busbar. Grounding lug: aluminum allog 6061-T6. Plastic metaliner prevents damage to wire insulation.
-
Split Bushing, Insulated, Grounding, Zinc Plated SteelUsed in situations where wires have already been pulled through Rigid/IMC conduit or EMT Fittings, and an insulated Grounding bushing is required. Grounding lug, aluminum alloy 6061-T6. Rated 150 Degree C. cULus listed. PatentedView Available Sizes
- 1-1/4"
- 1-1/2"
- 2"
- 2-1/2"
- 3"
- 3-1/2"
- 4"
-
Bushing, Insulated, Malleable IronUsed with locknut to terminate threaded rigid and IMC to box. Plastic metaliner prevents damage to wire insulation. 1/2" thru 4" rated 150 degree C, 5" and 6" rated 105 degree C.
-
Bushing, Reducing, Malleable IronUsed to reduce the size of internal female threads. 1/2" thru 2" steel, 2 1/2" thru 4" malleable iron.
-
Bushing Penny, SteelUsed inside bushing to prevent foreign matter from entering conduit. Galvanized steel.
-
Bushing, Insulating, Plastic Rated 105 Degrees CConverts metallic box rough edged knockout holes to smooth insulated holes for protection of electrical and telecommunications cable. Rated 105 Degrees C.
-
Split Bushing, Insulated, Plastic, PatentedUsed in situations where wires have already been pulled through Rigid/IMC conduit and an insulated bushing is required. Rated 105 Degree C. cULus listed.
-
Threadless Bushing, Insulated, Grounding, Malleable IronFor use on threadless rigid and IMC conduit where an insulated grounding bushing is required. Rated 150 Degree C. cULus listed. Patented
-
Bushing, Anti-Short, Redheads, PolyethylenePolyethylene "Redheads" prevent damage to wire installation when placed between the wire and armored sheath. Rated 90 degree C.View Available Sizes
-
Bushing, Insulated, Zinc Die CastUsed with locknut to protect conductors inside threaded rigid or IMC conduit entering a box. Plastic liner prevents damage to wire insulation. Plastic Metaliner - 150°
-
Bushing, Insulated, Grounding, Zinc Die CastUsed with locknut to terminate service conduit to cabinet. Lug provided for bonding jumper to neutral busbar. Grounding lug; aluminum alloy 6061-T6. Plastic metaliner prevents damage to wire insulation. Rated 150 degree C.